16. Meteorological standards

The basic meteorological standard is “GOST 12.1.005-88”, which regulates microclimate parameters and comprises thermal characteristic of work area, work category and year period. It provides standards for optimal and acceptable meteorological conditions.

Optimal meteorological conditions are provided by such microclimate parameters, which ensure normal thermal and functional condition of human organism without heat regulation stress. They give feeling of thermal comfort and create conditions for high productivity of workforce.

Acceptable meteorological conditions are provided by microclimate parameters, which may induce some changes of thermal and functional condition but heat regulation stress is relieved in short time. It doesn’t impact health, but may cause some discomfort and worsen workability.

Considering total energy consumption required for physical activity every work can be referred to easy, normal or hard work category.

Easy physical work (Category I) is activity with energy consumption up to 150 kilocalorie per hour (174 W).

Easy physical work divides into Category Ia - energy consumption up to 120 kilocalorie per hour (139 W) and Category Ib - energy consumption is 121-150 kilocalorie per hour (140-174 W).

Category Ia includes work in sitting or standing position what takes slight physical exertion (work applied in precise instrument-machine engineering, clothing manufacture, offices etc.).

Category Ib includes work in sitting, standing position or walking what takes some physical exertion (work applied in printing industry, communication service, checkers, experts in any industry etc.);

Normal physical work (Category II) is activity with energy consumption 151-250 kilocalorie per hour (175-290 W).

Normal physical work divides into Category IIa - energy consumption is 151-200 kilocalorie per hour (175-232 W) and Category IIb - energy consumption is 201-250 kilocalorie per hour (233-290 W).

Category IIa includes work with constant walking, moving small things (up to 1 kg weight) sitting or standing and takes some physical exertion (work applied in mechanical workshops, in machine engineering, spinning factory etc.).

Category IIb includes work with constant walking, moving and carrying weights up to 1 kg and takes moderate physical exertion (work applied in foundry, rolling, forge, heat and welding workshops etc.).

Hard physical work (Category III) is activity with energy consumption over 250 kilocalorie per hour (290 W).

Category III includes work with constant walking, moving and carrying heavy weights (over 10 kg) and takes great physical effort (work applied in forge workshops with manual ramming and casting in machine engineering and metallurgical works etc.).

The calendar year is divided into two periods: warm period having average daily temperature of external air +10 deg C and higher; and cold period - average daily temperature of external air below +10 deg C.

17. Meteorological monitoring

Mercury and alcohol thermometers are used to measure air temperature. The mercury thermometers are more precise in temperatures -35 ...+357 deg C. Alcohol thermometers are less precise and applied in low temperatures (under -130 deg C). The alcohol boils at temperature over 78.3 deg C.

Mercury thermometer indicates actual temperature at position of the upper part of meniscus, the alcohol - at the lower one.

Measuring air temperature in the area with the source of heat radiation they take pair-thermometer what’s made up from two thermometers. The surface of one of the mercury bulb is covered by black paint, and the other one is silver. The actual temperature is calculated taking both indications by the formula

ta = tb - k(tb-ts) , (8)

where tb - indication of thermometer with black bulb, deg C; k - instrument constant; ts - indication of thermometer with silvered bulb.

Time rating air temperature is read by thermograph.

Psychrometers are applied to measure air humidity. It consists from two thermometers - dry and wet one. The bulb of wet thermometer is covered with wet fabric; vaporizing from the bulb absorbs the heat, therefore the wet thermometer indication is lower than the dry one.

The most simply model of psychrometers is August psychrometer what’s made up from two alcohol thermometers - dry and wet one. The bulb of wet thermometer is covered by cambric the end of which is dipped into glass with distil water, which vaporizing from the bulb absorbs the heat, therefore the wet thermometer indication is lower than of the dry one.

More precise measurements use aspiration psychrometer (Asman psychrometer). It also consists from two thermometers the bulbs of which are in the metal sleeves, what prevents additional heating of thermometers by heat radiation. Protective sleeves connect to the pipe with aspiration ventilator set on its upper part.

Difference in thermometers’ indications is used to find humidity by psychrometeric table 1, or by formula.

, (9)

where f - partial pressure of saturated vapor at the temperature of wet thermometer, millimeters of mercury column (mm.mr.cl.) (table A.3); - psychrometerical coefficient, grad-1 (for psychrometers «M-34» and «MB-4M» = 0.0007 grad-1); t1 and t2 - indications of dry and wet thermometers accordingly, deg C; P - barometric pressure, mm.mr.cl.; M - partial pressure of saturated vapor at the temperature of dry thermometer, mm.mr.cl.

Time rating air humidity is read by hygrograph.

Table 1

Psychrometeric table

Wet thermometer indication,

°C

Air humidity, % , at the difference of dry and wet thermometers indications, deg C

3.0

3.5

4.0

4.5

5.0

5.5

6.0

6.5

7.0

7.5

8.0

8.5

9.0

8

67

62

57

53

50

46

42

39

36

32

30

27

24

9

69

64

59

55

51

51

44

40

37

34

32

29

26

10

70

65

60

56

53

53

46

43

40

36

34

31

28

11

70

65

61

57

54

54

47

44

41

38

35

32

30

12

71

66

62

58

55

55

48

45

42

40

37

34

32

13

71

67

63

59

56

56

50

47

44

41

39

36

34

14

72

68

64

60

57

57

51

48

45

42

40

37

35

15

73

69

65

62

58

58

52

49

47

44

42

39

36

16

73

70

66

62

59

59

53

50

48

45

43

40

38

17

74

70

67

63

60

60

54

52

49

46

44

41

39

18

75

71

68

64

61

61

55

53

50

47

45

43

40

For measuring air circulation in the frames of 0.3 ... 5 mps revolving-vane analyzer is applied. Its vane has light aluminium or micaceous vane placed into wide metal ring. The worm-gearing transfers the vane revolution to counter. The air circulation is defined by means of calibration graph taking the difference of counter indication before and after the measuring divided by time of measuring in seconds.

For measuring air circulation in the frames of 1 … 50 mps revolving-cup analyzer is applied.

To measure very slight air circulation electro-anemometers and catathermometer are used.

Catathermometer is alcohol thermometer with cylindrical or spherical bulb. Cylindrical catathermometer scale is calibrated in frames 35 .. 38 deg , spherical one - 33 .. 40 deg C.

The heat measured in milicalories, that 1 cm2 of bulb surface radiates for the time the catathermometer cools down from 38 to 35 deg C is called device factor F. It’s signed on the catathermometer capillary bore.

If to divide factor F by time a (in seconds), during which alcohol column of heated catathermometer goes down from 38 to 35 deg C, we’ll get the total cooling ability of air H:

. (10)

If measuring is carried out in the temperature frames 40 .. 33 deg C, or 39 .. 34 deg C

, (11)

where t’ - temperature at the beginning of measuring, deg C; t’’ - temperature at the end of measuring, deg C.

, (12)

or

, (13)

where t - difference between average temperature of catathermometer (36.5 deg C) and air temperature in room.

Heat radiation is measured by actinometer.